Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping

Includes: Installation guide

ACFD12-TFeatures

Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping

  • Coolant balancing
    Provides a central point for fluid balancing.
  • Front service access
    The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
  • Isolated cooling circuit
    A separate, isolated section which houses all cooling components minimizes the risk of water contacting installed IT equipment in the unlikely event of a leak.
  • Top and bottom chilled water connections
    Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.

InRow Chilled Water CoolingFeatures & Benefits

Manageability
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller
    Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
  • Real-Time Capacity Monitoring
    Real-time display of current and available cooling.
Agility
  • Casters
    Provides flexibility to move the unit to wherever cooling is required.
  • Scaleable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
Serviceability
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Availability
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Top and bottom chilled water connections
    Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
  • Rack inlet control
    Rack inlet control guarantees inlet temperature to IT equipment.
  • Dual A-B power inputs
    Draws power from the UPS for power protection with dual feeds for redundancy.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Total Cost of Ownership
  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.

    Physical

    • Maximum Height
      1991mm , 199.1cm
    • Maximum Width
      1070mm , 107.0cm
    • Maximum Depth
      750mm , 75.0cm
    • Net Weight
      269.56kg
    • Shipping weight
      314.56kg
    • Shipping Height
      2159mm , 215.9cm
    • Shipping Width
      1219mm , 121.9cm
    • Shipping Depth
      889mm , 88.9cm
    • Color
      Black
    • Units per Pallet
      1.0

    Conformance

    • Approvals
      MEA
    • Standard warranty
      1 year (parts only)

 